Your Network Guardian: The tcPDU with Watchdog & SMS Backup
Every admin's biggest worry? A system failure when no one is on site. The tinycontrol tcPDU 4G elegantly and reliably solves this problem. Its core function, the 19-inch power strip with watchdog function, is your personal lifeline. Simply define up to five critical IP addresses in your Network – for example, your Router, an Ethernet Switch, or a server. If one of these devices no longer responds to a Ping, the tcPDU automatically intervenes and performs a hard reset by briefly turning the assigned outlet off and on again. Even if the primary internet connection fails, the PDU remains fully accessible thanks to the integrated 4G modem. This way, a server restart via SMS outlet is possible at any time, and you maintain control over your Network.
More Than Just Power: Your Central Monitoring System in the Rack
Transform your power distribution into an intelligent command center. The tcPDU 4G is a full-fledged power distributor with sensor connection for 19-Inch Rack environments. Via the RJ-12 port, you can directly connect up to eight DS18B20 temperature sensors or combined temperature and humidity sensors. Precisely monitor the climate conditions in your cabinet and receive warnings before overheating occurs. The two additional logic inputs are perfect for door contact sensors or for monitoring other external states. All collected data can be accessed via the web interface, SNMP, or MQTT and can be used for automations.
Intelligent Automation for Professionals
The true strength of the tcPDU 4G lies in its flexibility. With the Scheduler, you can define time-controlled switching operations – ideal for regular restarts or for saving energy outside business hours. The 'Events' engine goes a step further: here you can link up to three logical conditions to create complex scenarios. A practical example: 'IF the temperature in the Rack rises above 35°C AND the door contact reports 'closed', THEN switch on the output for the auxiliary fans'. Such intelligent rules ensure proactive and automated protection of your valuable hardware within your Network.
Strengths & Notes at a Glance
- Pro: The combination of Ethernet and 4G modem offers unparalleled reliability and remote access capabilities for your Network.
- Pro: The highly developed Event engine enables complex automations based on sensor values and logical connections.
- Pro: Integrated environmental and energy monitoring makes the PDU a central monitoring unit in the 19-Inch Rack.
- Pro: The robust IP-Watchdog for up to five devices ensures automatic Service restoration.
- Note: Energy measurement only records the total consumption of all outlets, not individual channel measurement.
- Note: The Ethernet Port is limited to 10/100 Mbit/s, which is completely sufficient for control tasks.
Specifications & Features
| Manufacturer: | tinycontrol |
| Model: | tcPDU 4G |
| EAN: | 5906111106288 |
| Manufacturer Part Number (MPN): | 06288 |
| Product Type: | Managed Power Distribution Unit (PDU) |
| Housing Form: | 19-Inch Rack Standard |
| Dimensions (H x W x L): | 45 x 90 x 440 mm (without handles) |
| Length with Handles: | 490 mm |
| Weight: | 1.80 kg |
| Color: | Black / White |
| Number of Outlets: | 7, independently switchable |
| Outlet Type: | Type E (French) or Type F (Schuko/German) |
| Input Voltage: | 230 V AC (+/- 10%) |
| Connection Cable: | 1.35 m with Uni-Schuko plug |
| Maximum Load Current: | 10 A (AC1 category) |
| Maximum Output Power: | 2300 W (AC1), 750 W (AC3) |
| Overload Protection: | 10 A circuit breaker (front) |
| Overvoltage Protection: | Varistor and 15 A fuse (rear) |
| Ethernet Port: | 1x RJ-45 (10/100 Mbit/s) |
| Mobile Connectivity: | Integrated 4G modem (Internet via PPP, SMS control) |
| Sensor Bus: | 1x RJ-12 (for I2C / 1-Wire) |
| Logical Inputs: | 1x 4-Pin-Terminal for 2 digital inputs |
| Management Protocols: | HTTP/HTTPS, SNMPv2/v3 (with Traps), MQTT (with TLS), HTTP-API |
| Notifications: | E-Mail, SNMP-Traps |
| Time Synchronization: | NTP server |
| Energy Measurement: | Voltage, Current, Active/Reactive Power, Energy Consumption (total value) |
| 1-Wire Sensor Support: | Up to 8x DS18B20 Temperature Sensors |
| I2C Sensor Support: | Temperature & Humidity Sensors (e.g., AM2301B) |
| Fuse Monitoring: | Yes, detects status of the circuit breaker |
| IP-Watchdog: | Monitors up to 5 IP addresses via Ping |
| Scheduler (Time Planner): | Yes, one-time and periodic |
| Event Control: | Yes, based on up to 3 logical conditions |
| SMS Control: | Yes, status query and switching of outputs |
| CLIP Function: | Yes, switching an output by call |
| User Management: | Administrator and user accounts |
| Firmware: | Upgradeable via web interface |
Scope of Delivery
| 1 x tinycontrol tcPDU 4G |
Frequently Asked Questions (FAQ)
Can the tinycontrol tcPDU 4G restart individual outlets during an internet outage?
Yes, this is a core function. Using the integrated IP-Watchdog, the PDU can ping a device (e.g., a Router). If it doesn't respond, the PDU can automatically switch the corresponding outlet off and on again to force a restart of the Network device.
Is it possible to control the PDU via SMS without a Network connection?
Yes, the 4G version is specifically designed for this. You can send commands to switch the outputs (on, off, reboot) via SMS to the SIM card in the PDU.
Which sensors can I connect directly to the tcPDU?
You can connect digital temperature sensors (DS18B20) as well as I2C sensors for temperature and humidity via the RJ12 port. Additionally, it has two logic inputs for contact sensors, such as door or window contacts.
Does the tcPDU support integration into Smart Home systems like Home Assistant?
Yes, there is an official integration for Home Assistant, which allows reading sensor values and controlling the tcPDU outputs directly from Home Assistant.
Does the PDU measure power consumption for each individual outlet?
No, the integrated energy measurement records the total consumption of voltage, current, and power for all seven outlets combined, not per individual port.